Name: DRYING OVENS
Code: 12004
Description: DRYING OVENS, These ovens are specially designed for testing laboratories of construction industry. Temperature range: from 50°C to 250°C, Operation on 230V 50-60Hz. Single phase, AC Mains, Or 110v 50-60Hz. Single phase on request
Code: 12004
Description: DRYING OVENS, These ovens are specially designed for testing laboratories of construction industry. Temperature range: from 50°C to 250°C, Operation on 230V 50-60Hz. Single phase, AC Mains, Or 110v 50-60Hz. Single phase on request
Name: DIGITAL MICROWAVE OVEN
Code: 12004-10
Description: Digital Microwave Oven, Operation On 230v, 50 Hz., Single Phase Ac. Capacity: 20 Ltr, 25 Ltr, 30 Ltr.
Code: 12004-10
Description: Digital Microwave Oven, Operation On 230v, 50 Hz., Single Phase Ac. Capacity: 20 Ltr, 25 Ltr, 30 Ltr.
Name: AUTOCLAVE
Code: 12012
Description: AUTOCLAVE, Cylindrical Triple Walled, Three chamber body Jacketed Model with microprocessor based PID controller and Timer.
Code: 12012
Description: AUTOCLAVE, Cylindrical Triple Walled, Three chamber body Jacketed Model with microprocessor based PID controller and Timer.
Name: MUFFLE FURNACE
Code: 12015-00
Description: ’CI’ MUFFLE FURNACE: DIGITAL MICROPROCESSOR CONTROL, Light weight with ceramic fibre wool and block insulation. Body is of double walled C.R. Sheet light grey/white powder coated. Temp. Range900°C,Max. temp. 1050C.Operation on 220/230V AC mains, 50Hz single phase.
Code: 12015-00
Description: ’CI’ MUFFLE FURNACE: DIGITAL MICROPROCESSOR CONTROL, Light weight with ceramic fibre wool and block insulation. Body is of double walled C.R. Sheet light grey/white powder coated. Temp. Range900°C,Max. temp. 1050C.Operation on 220/230V AC mains, 50Hz single phase.
Name: B O D INCUBATOR
Code: 12016
Description: B O D Incubator, Double Walled Construction With Outer Of Anti-Corrossive Powder Coated C.R. Sheet, Inner Of S.S.304 And Adjustable Welded Mesh Rod Powder Coated Trays
Code: 12016
Description: B O D Incubator, Double Walled Construction With Outer Of Anti-Corrossive Powder Coated C.R. Sheet, Inner Of S.S.304 And Adjustable Welded Mesh Rod Powder Coated Trays
Name: BOD MEASUREMENT SYSTEM BD 600
Code: 12016
Description: Bod Measurement System Bd 600, Bod - Biochemical Oxygen Demand Is An Expression For The Quality Of Oxygen Required For Biological Degradation Of Organic Matter In A Waste Water Sample. .
Code: 12016
Description: Bod Measurement System Bd 600, Bod - Biochemical Oxygen Demand Is An Expression For The Quality Of Oxygen Required For Biological Degradation Of Organic Matter In A Waste Water Sample. .
Name: COD THERMO REACTOR RD125
Code: 12016
Description: Cod Thermo Reactor Rd125, Test Range : Cod Lr : 0-150mg/L, Cod Mr: 0-1500mg/L, Cod Hr : 0-15000mg/L. Abs Housing, Pps Protection Grid, Pc Lid, Pbt Block Insert. Heating Block Made Of Aluminium. 24 Holes In The Aluminium Block Of 16.2 Mm ±0.2 Mm
Code: 12016
Description: Cod Thermo Reactor Rd125, Test Range : Cod Lr : 0-150mg/L, Cod Mr: 0-1500mg/L, Cod Hr : 0-15000mg/L. Abs Housing, Pps Protection Grid, Pc Lid, Pbt Block Insert. Heating Block Made Of Aluminium. 24 Holes In The Aluminium Block Of 16.2 Mm ±0.2 Mm
Name: COD DIGESTION UNIT
Code: 12016
Description: Cod Digestion Unit, The Cod Digestion Unit Is Used For Determination Of Chemical Oxygen Demand In Effluents. Compact Design With No Water Circulation.
Code: 12016
Description: Cod Digestion Unit, The Cod Digestion Unit Is Used For Determination Of Chemical Oxygen Demand In Effluents. Compact Design With No Water Circulation.
Name: HUMIDITY CABINET / ENVIRONMENTAL CHAMBER
Code: 12017
Description: Humidity Cabinet, Temperature Range : 10°C Above Ambient To 60°C. Humidity : 5% Above Ambient To 98%. Accuracy Of Temp : ± 1% And Humidity Control ± 5% Rh. Chamber Size : As Per Requirement (Minimum 6 Cft)
Code: 12017
Description: Humidity Cabinet, Temperature Range : 10°C Above Ambient To 60°C. Humidity : 5% Above Ambient To 98%. Accuracy Of Temp : ± 1% And Humidity Control ± 5% Rh. Chamber Size : As Per Requirement (Minimum 6 Cft)
Name: RING WATER BATH
Code: 12020
Description: Ring Water Bath, Inner Stainless Steel. Temp. Range 50c Above Ambient To 1000c. Top Cover Having Holes Of 75mm Diameter With Concentric Rings. Operation On 230v Ac Mains. (Digital )
Code: 12020
Description: Ring Water Bath, Inner Stainless Steel. Temp. Range 50c Above Ambient To 1000c. Top Cover Having Holes Of 75mm Diameter With Concentric Rings. Operation On 230v Ac Mains. (Digital )